1. Foundation
Reinforced concrete foundation to engineer's requirements
2. Super-structure
Reinforced concrete structure to engineer's requirements
3. Walls
External
-Pre-cast concrete panels and/or common clay brick to Architect & Engineer's requirements
Internal
-Pre-cast concrete panels and/or common clay brick to Architect & Engineer's requirements
4. Roof
Reinforced concrete flat roof
5. Ceiling
Living/Dining/Bedrooms
-Skim coat and/or plaster ceiling boards with emulsion Paint to Architect's selection
Household Shelter, Balcony & Private Terrace
-Skim coat with emulsion paint to Architect's selection
Bathroom/Kitchen
-Moisture resistant plaster ceiling boards with emulsion paint finish to Architect's selection
6. Finishes
Wall (For Apartments)
Living/Dining/Bedrooms/Kitchen/Household Shelter/Balcony
-Cement and Sand plaster and/or skim coat with emulsion paint to Architect's selection
Bathroom
-Homogeneous and/or Ceramic tiles lay up to false ceiling height (exposed area only) to Architect's design (Note: For Types G1 & G2 only - These units have a high floor to ceiling height of 6.0m. The internal brickwall/pre-cast panels/paritions of the bedrooms and toilets will be built to a height of 3.25m only)
Wall (For Common Areas)
1st Storey Lift Lobbies/Typical Lift Lobbies/Staircases
-Cement and sand plaster and/or skim coat with emulsion paint to Architect's selection
External Wall
-Cement and sand plaster and/or skim coat with weather resistant paint to Architect's selection
Floor (For Apartments)
Living/Dining/Kitchen/Bedroom/Study
-Compressed marble and/or Homogeneous tiles to Architect's selection
Bathroom
-Ceramic and/or homogeneous tiles to Architect's selection
Household Shelter/Balcony/Private Terrace
-Ceramic and/or homogeneous tiles to Architect's selection
Planter Box
-Cement & Sand screeding
A/C Ledge
-Cement & Sand screeding
Private Pool (where applicable)
a) Pool
-Mosaic and/or ceramic tiles to Architect's selection
b) Pool Deck
-Ceramic tiles and/or timber deck to Architect's selection
Floor (Common Areas)
a) 1st Storey Lift Lobbies
-Homogeneous and/or Ceramic tiles to Architect's selection
b) Typical Lift Lobbies
-Homogeneous and/or Ceramic tiles to Architect's selection
c) Staircases
-Cement & Sand screed with nosing tiles to Architect's selection
d) Sky Terrace/Sun Deck/Pool Area
-Ceramic tiles and/or timber deck to Architect's selection
e) Swimming Pool
-Mosaic and/or ceramic tiles to Architect's selection
f) Walkway/Pavement
-Pebbles wash and/or Homogeneous and/or ceramic tiles to Architect's selection
7. Windows
Powder coated aluminium framed windows with approx. 6mm thick tinted floar glass to Architect's selection
8. Doors
a) Main Entrance
-Fire-rated timber door to Architect's design
b) Bedrooms/Bathrooms
-Semi-hollow core timber door to Architect's design
c) Household Shelter
-Approved blast door
d) Ironmongery
-Locksets and hinges to Architect's selection
9 .Railings
Stainless steel and/or mild steel with paint to Architect's selection
10. Sanitary wares and fittings
Bathroom
a) 1 shower cubicle with shower mixer, rain shower head and shower set to Architect's selection
b) 1 wash basin and mixer tap to Architect's selection
c) 1 water closet to Architect's selection
d) 1 mirror to Architect's design
e) 1 toilet paper holder to Architect's selection
11. Electrical Installation/Telephone/TV/FM
a) All electrical wiring are concealed in floor and wall in conduits wherever possible except for electrical wiring above false ceiling, household shelter, and DB cabinet will be exposed in trunking and/or conduits
b) Refer to Electrical Schedule for details
12. Lightning Protection System
a) Lightning Protection System shall be provided in accordance with Singapore Standard CP33 1996
13. Painting
a) External Walls
-Spray textured coating and/or Weather resistant emulsion paint to Architect's selection
b) Internal Walls
-Emulsion paint to Architect's selection
14. Waterproofing
a) Waterproofing is provided to floors of Bathrooms, Kitchen, Balcony, W.C., R.C flat roof, Planter Box and where required
15. Driveway & Carpark
a) Surface Driveway
-Interlocking pavement and/or concrete imprint to Architect's selection
b) Mechanical Carpark Systems
-According to specialist's specifications
16. Recreational Facilities
a) Swimming Pool
b) Jacuzzi
c) Cascading Water Feature
d) Pool Deck
e) Outdoor Gymnasium
f) BBQ Area
g) Landscaping
h) Children's Play Area
i) Wet Deck
17. Other Items
a) Kitchen Cabinets
-High and low kitchen cabinets with solid surface work top complete with sink and mixer to Architect's design & selection
b) Kitchen Appliances
-Cooker Hob and cooker hood, integrated fridge and washer-cum-dryer to Architect's selection
c) Bedroom Wardrobes
-Built-in wardrobes to all bedrooms to Architect's design & selection
d) Air-conditioning
-Multi-split air-conditioning to all Bedrooms and Living/Dining to M & E Engineer's selection
e) Audio/Intercom System
-Gate post with audio intercom to apartment units to M & E Engineer's selection
f) Electric Water Heater
-Hot water supply to all bathrooms and kitchen except W.C. to M&E Engineer's requirements
g) Soil Treatment
-Anti-termite soil treatment by specialist's specifications
h) Cable Vision
-Provision of cable and outlet only