1. Foundation
-Pile to engineer's design.
2. Superstructure
-Reinforced concrete using Grade 30 and/or 35 concrete manufactured from Portland Cement complying with SS26 steel reinforcement bar complying with SS22.
3. Walls
a) External Walls :
-Reinforced concrete and/or common clay brick walls.
b) Internal Walls :
-Reinforced concrete and/or precast panels (light weight) and/or dry wall panels and/or common clay brick walls.
4. Roof
-Reinforced concrete flat roof and/or metal roof. Roof structure of reinforced concrete and/or tanalised timber and/or mild steel.
5. Ceiling
For Apartments
a) Living/ Dining, Bedrooms Study, Balcony, Yard :
-Skim coat and/or ceiling board with emulsion paint finish.
b) Bathrooms and Kitchen :
-Skim coat and/or water resistant ceiling board with emulsion paint finish.
c) Household Shelter :
-Skim coat with emulsion paint finish.
For Common Areas
a) Lift Lobbies :
-Skim coat and/or ceiling board with emulsion paint finish.
b) Carpark :
-Skim coat with emulsion paint finish.
c) Staircases :
-Skim coat with emulsion paint finish.
6. Finishes
Wall For Apartments
a) Living/Dining, Bedrooms, Study, Household Shelter, Staircase :
-Plaster and/or skim coat with emulsion paint finish.
b) Master Bath, Common Bathrooms :
-Marbles and/or ceramic tiles and/or homogenous tiles finish
c) Open Terrace, Balcony, Yard :
-Plaster and/or skim coat with emulsion paint finish.
Note: No tiles/stone behind mirrors and above false ceiling.
For Common Areas
a) 1st Storey Lift Lobby :
-Ceramic tiles and/or stones and/or plaster with emulsion paint finish.
b) Typical Lift Lobbies, Corridors :
-Ceramic tiles and/or homogenous tiles and/or plaster and/or skim coat with emulsion paint finish.
c) Carpark and Ramps :
-Plaster and/or skim coat with emulsion paint finish.
d) Corridors :
-Plaster and/or skim coat with emulsion paint finish.
e) Staircases :
-Plaster and/or skim coat with emulsion paint finish.
Floor For Apartments
a) Living/Dining :
-Marble tiles and/or compressed marble with timber and/or tiles skirting finish.
b) Open Terrace, Balcony :
-Ceramic tiles and/or stones tiles finish.
c) Kitchen :
-Marbles and/or compressed marble and/or ceramic tiles and/or homogenous tiles finish.
d) Household Shelter, Yard :
-Ceramic tiles and/or homogenous tiles finish.
e) Master Bath, Common Bathrooms :
-Marbles and/or ceramic tiles and/or homogenous tiles finish.
f) Bedrooms, Study, Staircase (Penthouse Only) :
-Random teak strips flooring with timber skirting finish.
g) Planter Boxes, A/C Ledges :
-Cement screed with paint finish.
For Common Areas
a) 1st Storey Lift Lobby :
-Ceramic tiles and/or stones tiles with skirting tiles finish.
b) Typical Lift Lobbies, Corridors :
-Ceramic tiles and/or homogenous tiles with skirting tiles finish.
c) Carpark and Ramps :
-Cement and sand screed finish.
d) Deck, Gymnasium, Walkway :
-Ceramic tiles and/or stones tiles finish.
e) Staircases :
-Cement and sand screed finish with nosing.
7. Windows
Powder coated aluminum framed with approximately 6 mm glass.
8. Doors
Aluminium with glass/acrylic or decorative timber or decorative timber with glass panel or glass panel. Steel door for house shelter as per requirement of authority. Quality imported locks brand 'VBH' or equivalent.
9. Sanitary fittings
a) Master Bathroom
-1 sunken bath (if any) with shower mixer and rainshower set and shower set.
-1 basin and mixer tap
-1 pedestal water closet
-1 mirror
-1 toilet paper holder
b) Common Bathroom
-1 shower bath with shower mixer and shower set.
-1 basin and mixer tap
-1 pedestal water closet
-1 mirror
-1 toilet holder
10. Electrical Installation
-All electrical wiring to be in concealed conduits and main in surface trunking/pipes. Where there is a false ceiling, the electrical wiring above false ceiling is in exposed conduits. Mechanical ventilation provided in bathroom (if required). Refer to Electrical Schedule for details.
11. TV/Telephone
-TV/telephone points shall be provided in accordance to the Electrical Schedule.
12. Lightning Protection
Lightning protection system shall be provided in accordance with the current edition of Singapore Code of Practice.
13. Painting
a) Internal wall :
-Emulsion water-based paint.
b) External wall :
-Selected oil-based base coat and water-based exterior paint.
14. Water
-Proofing Waterproofing to reinforced concrete flat roof and bathrooms (if any).
15. Driveway and Car Park
-Concrete floor and/or ceramic and/or stone finish.
16. Recreation Facilities
-The followings are provided:
a) Swimming pool
b) Jacuzzi
c) BBQ
d) Gymnasium
17. Additional Items
a) Kitchen Cabinets
-High and low kitchen cabinets with solid surface countertop complete with gas hob and cooker hood ("BOSCH" brand or equivalent) . One stainless steel sink complete with tap.
b) Wardrobes
-Built-in wardrobes to all bedrooms (if any).
c) Air-Conditioning
-Split type air conditioner ("DAIKIN" or equivalent) provided in living, dining, and bedrooms/Study.
d) Water Heater
-Heater of "Ariston" or equivalent.
e) Railing
-Mild steel for common stair railing. Steel and/or glass for other railings.
f) Security
Audio intercom to all units.
g) Lift
-1 passenger lifts ("KONE" or equivalent) from first to fifth floor.
h) Fencing
-Brickwall and/or steel railing on brickwall. Selected area decorated with glass.