Oxley BizHub 2 – where cutting-edge business blends seamlessly with modern lifestyle luxuries.
Soar your business to new heights at Oxley BizHub 2, a metropolitan industrial and lifestyle complex that is strategically located in the industrial district along Ubi Road 1.
In continuing with the concept of Oxley BizHub just across the street and situated in between the upcoming business hubs of Paya Lebar Central and MacPherson Interchange, there is no better location from which to propel your business forward. Combines modern work culture with thoughtfully planned lifestyle amenities to give your business a unique edge that will distinguish you from your competitors.
Making connections just got easier…
• Unbeatable frontage along Ubi Road 1
• Approximate 5 minutes walk to Tai Seng MRT
• Only 2 stations away from Paya Lebar MRT
• Easy access to major expressways such as Kallang-Paya Lebar Expressway and Pan Island Expressway
• Just 10 – 15 minutes away from Changi Airport, Singapore’s CBD and Integrated Resorts
An outstanding development that reflects the outlook of a modern business lifestyle.
•Beautiful development comprising a single tower block atop a 3-storey podium
• Iconic design with free-flowing curves make Oxley BizHub 2 stand out from its neighbours
• Ample space suitable for both warehouse and factory units
• Vibrant lifestyle amenities such as a gym, swimming pool and lush landscaping make coming to work a pleasure to look forward to
• Canteen with myriad dining options on the 11th storey provides dining with a view
Awe inspiring architecture that complements your business aspirations.
An unexpected lifestyle in tandem with your ever-growing business – only at Oxley BizHub 2.
Spacious units with mezzanine floors add a spectacular touch to your business.
Work off the stress of the business day in the gym or relax with breathtaking view at the pool deck.
Oxley Bizhub 2 Location Map
Oxley Bizhub 2 Street View
Oxley Bizhub 2 Resale/Rental Prices
Floor Plans
Oxley Bizhub 2 Site Map
Oxley Bizhub 2 1st Storey Floor Plans
Oxley Bizhub 2 2nd Storey Floor Plans
Oxley Bizhub 2 3rd Storey Floor Plans
Oxley Bizhub 2 4th/5th Storey Floor Plans
Oxley Bizhub 2 6th to 10th Storey Floor Plans
Oxley Bizhub 2 11th Storey Floor Plans
Specifications
1. Foundation Concrete RC Pile
2. Superstructure Reinforced concrete columns. Reinforced/ Post tensioned concrete to beams and floor slabs.
3. Roof Reinforced/ Post tensioned concrete flat roof with waterproofing.
4. Floor Live Loading Warehouse (1st to 2nd storey) 7.5 kN/m2 Production Unit (3rd to 11th storey) 5.0 kN/m2 1st, 3rd & 11th storey mezzanine 3.0 kN/m2 3rd storey landscape area 5.0 kN/m2 Gym room and canteen 5.0 kN/m2 Storey driveway and carpark 2.5 kN/m2 Roof (not accessible) 0.75kN/m2
5. Floor to Floor Height 1st Storey (inclusive of Mezzanine floor) 7 metres approximately 2nd Storey 4 metres approximately 3rd Storey (inclusive of Mezzanine floor) 7 metres approximately 4th Storey to 9th Storey 4 metres approximately 10th Storey* 5 metres approximately 11th Storey* (inclusive of Mezzanine floor) 6 metres approximately
* Exclusive of following units * 10th storey unit 19, 20 & 21 6.5 metres approximately * 10th storey unit 15, 16, 17 & 18 4.6 metres approximately * 10th storey unit 14 4.1 metres approximately * 11th storey unit 01 & 02 5.0 metres approximately * 11th storey unit 19 (ancillary canteen) 3.8 metres approximately
6. External Walls RC wall and/or clay brick wall and/or precast panel with skim coat and/or plaster with weathershield emulsion paint finish, where applicable or equivalent.
7. Internal Walls RC wall and/or clay brick wall and/or precast panel wall with skim coat and/or plaster with emulsion paint finish,where applicable. Homogenous tiles and/or granite tiles and/or plaster with emulsion paint finish, where applicable. Homogenous and/or ceramic tiles finishes to toilet wall, where applicable.
8. Ceiling Generally concrete ceiling soffit with skim coat and acrylic emulsion paint except lift lobbies, corridors, toilets with calcium silicate board suspended ceiling and/or gypsum ceiling.
9. Flooring Generally power floated concrete floor to all areas except lift lobbies in homogenous and/or granite tile finishes and toilet areas in ceramic and/or homogenous tiles.
10. Doors Glass and/or timber doors and PSB’s approved fire-rated doors where applicable.
11. Locks Good quality locksets and ironmongery.
12. Windows Power-coated aluminium framed glass window system
13. Electrical Installation 40Amps 3 Phase #01-01 to 03, #01-42(FCC/MCST); #02-01 to 06; #04-02 to 13, 15 to 26; #05-02 to 13, 15 to 26; #06-02 to 13, 15 to 26; #07-02 to 13, 15 to 26; #08-02 to 13, 15 to 26; #09-02 to 13, 15 to 26; #10-02 to 13, 15 to 26; #11-02, 13;
60Amps 3 Phase #01-04 to 41; #03-01 to 23; #04-01, 14; #05-01, 14; #06-01, 14; #07-01, 14; #08-01, 14; #09-01, 14; #10-01, 14; #11-01, 03 to 12, 14 to 18;
100Amps 3 Phase #11-19 (Ancillary Canteen);
Exit and Emergency lights in each unit
14. Sanitary Installation Good quality sanitary wares and fittings in compliance with statutory requirements
15. Air-Conditioning and Mechanical Ventilation Provision of air-conditioning to selected lift lobbies & internal common corridor, mechanical ventilation to serve common toilets and carparks complied with authority requirements.
16. Lift 4 service lifts 2 passenger lifts
17. Fire Protection System Sprinkler and Fire Alarm System in compliance with statutory requirements. Dry Risers and Hose-reel System in common areas
18. Lightning Protection Lightning protection is provided to comply with latest code of practices.
19. Telecommunication Services Cable tray from MDF room to telephone risers and common corridors. Telephone point is provided to each unit with the box terminal.
20. Recreation Facilities Gymnasium Swimming Pool
Note: Tiles: Selected tiles sizes and tile surface flatness cannot be perfect, and subject to acceptable range described in Singapore Standards SS483:2000.
Ventilation: Natural and/or mechanical ventilation as required by the Building and construction Authority (BCA) and/or National Environment Authority (NEA).
Business Use: The purchaser will not use the unit or permit to be used for any purpose save for the approved use of the competent authority appointed under the Planning Act (Cap. 232) for “Business 1” zoning in accordance with the Master Plan Written Statement 2008.
E-Brochure
Oxley Bizhub 2 E-Brochure
Reviews
There are no reviews yet.
Be the first to review “Oxley Bizhub 2” Cancel reply
Chat With Us Today!
Own your dream property stress-free. We go beyond real estate. Our interior design-trained realtors provide a one-stop shop for all your property needs: buying, selling, renting, and everything in between. We will help you with financing and tax planning, investment analysis and portfolio management, timeline planning and space optimization and even interior design assistance before renting or purchasing the property. Get a free consultation today and let our professionals guide you every step of the way.
Reviews
There are no reviews yet.