Developer: Oxley Rising Pte Ltd Architect: AC Consortium Site Area: 34,852.6 sqm or 375,153 sqft No. Of Units: 390 Production Units + 336 Warehouse Units + 2 Staff Canteen Tenure: 60 years wef 15 November 2010 District: 14 TOP: 2014 Unit Types:
138 warehouse units with loft (1410 to 3423 sqft)
198 warehouse units (915 to 2476 sqft)
2 unit ancillary staff canteen (6071 to 9300 sqft)
280 production units (936 to 3186 sqft)
110 production units with loft (1873 to 2390 sqft)
A New Beginning. Welcome to a revolutionary industrial complex, Oxley BizHub.
Strategically located with a wide frontage along Ubi Road 1, between the lively and vibrant future business hubs, Paya Lebar Central and MacPherson Interchange, Oxley BizHub is set to be the heart of the industrial district. With a working lifestyle in mind, Oxley BizHub is designed to boost morale and inspire productivity, drive your business to the next level.
Oxley BizHub, a first of its kind in Singapore.
Convenience and Accessibility
• Prominent frontage along Paya Lebar Road and Ubi Road 1.
• Approximate 5 minutes walk to Tai Seng MRT.
• A stone’s throw away from Paya Lebar MRT Interchange station (Circle & East-West lines)
• Major link roads and expressways such as Kallang-Paya Lebar Expressway, Pan Island Expressways are within easy access.
• Approximate 10 to 15 minutes to Changi Airport, Central Business District and Integrated Resorts.
A Vibrant Business Hub for your Business Needs
• Prestigious development with 3 podiums and 4 towers.
• Iconic architectural design with full length windows ensure ample lighting and a beautiful open space to work in.
• Abundant basement and ramp-up car parks for easy loading & unloading, link bridges for vehicular access.
• Suitable for warehouse, factory, ancillary office with washroom attached in every unit.
• Loft units boast double volume heights and spectacular mezzanine floors.
• Ground floor canteens for your convenience.
Indulge Your Senses
Melt away the stress of a day’s work, wellness awaits you at the rooftop pool and gym. Escape from the hustle and bustle as lush eco-gardens provide the rejuvenation you deserve.
Lush eco-gardens provide the rejuvenation you deserve.
Escalators and link bridges for convenience and accessibility.
Loft Units Boast Volume Heights and Spectacular Mezzanine Floors
2. Superstructure Reinforced concrete columns. Reinforced/ Post tensioned concrete to all beams and floor slabs.
3. Roof Reinforced/ Post tensioned concrete flat roof with waterproofing.
4. Floor Live Loading 1st Basement (heavy vehicles) 15 kN/m2 1st Basement (cars) 2.5 kN/m2 1st Storey to 4th Storey (units area and driveway) 7.5 kN/m2 1st Storey to 4th Storey (landscape area) 5 kN/m2 5th Storey to 10th Storey 5 kN/m2 1st, 4th, 9th & 10th Storey Loft 5 kN/m2 Roof 1.5kN/m2 or M&E equipment loading
5. Floor to Floor Height 1st Basement 4.4 ~ 5.9 metres approximately 1st Storey (inclusive of Loft) 7 metres approximately 2nd Storey & 3rd Storey 6 metres approximately 4th Storey (inclusive of Loft) 7 metres approximately 5th Storey to 8th Storey 4.2 metres approximately 9th Storey (inclusive of Loft) & 10th Storey (inclusive of Loft) 6.5 metres approximately
6. External Walls RC wall and/or clay brick wall and/or hollow block wall with skim coat and/or plaster with weathershield emulsion paint finish, where applicable.
7. Internal Walls RC wall and/or clay brick wall and/or hollow block wall and/or precast panel wall with skim coat and/or plaster with emulsion paint finish, where applicable. Homogenous tiles and/or granite tiles and/or plaster with emulsion paint finish, where applicable. Homogenous and/or ceramic tiles finishes to toilet wall, where applicable.
8. Ceiling Generally concrete ceiling soffit with skim coat and acrylic emulsion paint except lift lobbies, corridors, toilets with calcium silicate board suspended ceiling.
9. Flooring Generally power floated concrete floor to all areas except lift lobbies in homogenous and/or granite tile finishes and toilet areas in ceramic and/or homogenous tiles.
10. Doors Glass and/or timber doors and PSB’s approved fire-rated doors where applicable.
11. Locks Good quality locksets and ironmongery.
12. Windows Power-coated aluminium framed glass window system.
13. Electrical Installation
40Amps 3 Phase Block 61, 63 & 65 #01-03 to 08,10,11,16,22 to 32,34,38 to 45,47,48,50,53,66,68 to 71,76,78 to 85,89 to 91; #02-02,to 06,09 to 20,22 to 40,42 to 46,48,49,51 to 58,62,64 to 69,71 to 80,82 to 97; #03-01 to 31,33 to 45,47,48,50 to 57,60 to 80,82 to 95; #04-01 to 48;
Block 67 #05-01 to 06,08 to 15; #06-01 to 06,08 to 15; #07-01 to 06,08 to 15; #08-01 to 06,08 to 15; #09-01 to 06,08,11,13 to 15; #10-01 to 06,08,11,13 to 15;
Block 69 #05-16 to 33; #06-16 to 33; #07-16 to 33; #08-16 to 33; #09-16 to 33; #10-16 to 33;
Block 71 #05-34 to 41,43 to 45, 47; #06-34 to 41,43 to 45, 47; #07-34 to 41,43 to 45, 47; #08-34 to 41,43 to 45,47; #09-34,36,38,40,41,43,44,47; #10-34,36,38,40,41,43,44,47;
Block 73 #05-49 to 65; #06-49 to 65; #07-49 to 65; #08-49 to 65; #09-50 to 65; #10-50 to 65;
60Amps 3 Phase Block 61, 63 & 65 #01-01,02,09,12 to 15,18 to 21,33,35,36,46,49,51,52,54 to 65,67,72,73,75,77,86 to 88,93 to 98; #02-01,07,08,21,41,47,50,59,60,61,63,70,81, #03-32,46,49,58,59,81,
14. Sanitary Installation Good quality sanitary wares and fittings in compliance with statutory requirements.
15. Air-Conditioning and Mechanical Ventilation Provision of air-conditioning to selected lift lobbies, mechanical ventilation to serve lift lobbies, toilets and carparks complied with authority requirements.
16. Lift & Escalators 9 service lifts 6 passenger lifts (inclusive of 4 fire-fighting lifts) 3 pairs of escalators
17. Fire Protection System Sprinkler and Fire Alarm System in compliance with statutory requirements. Dry Risers and Hose-reel System in common areas
18. Lightning Protection Lightning protection is provided to comply with latest code of practices.
19. Telecommunication Services Cable tray from MDF room to telephone risers and common corridors. Telephone point is provided to each unit with the box terminal
20. Recreation Facilities Gymnasium Swimming Pool
Note: Business Use The purchaser will not use the unit or permit to be used for any purpose save for the approved use of the competent authority appointed under the Planning Act (Cap. 232) for “Business 1” zoning in accordance with the Master Plan Written Statement 2008.
E-Brochure
Oxley Bizhub E-Brochure
Reviews
There are no reviews yet.
Be the first to review “Oxley Bizhub” Cancel reply
Chat With Us Today!
Own your dream property stress-free. We go beyond real estate. Our interior design-trained realtors provide a one-stop shop for all your property needs: buying, selling, renting, and everything in between. We will help you with financing and tax planning, investment analysis and portfolio management, timeline planning and space optimization and even interior design assistance before renting or purchasing the property. Get a free consultation today and let our professionals guide you every step of the way.
Reviews
There are no reviews yet.