Royal Square

Developer: Hoi Hup Sunway Novena Pte Ltd
No. Of Units: 25 Shops, 26 Restaurants, 171 Medical Suites
Tenure: 99 year leasehold wef 6 March 2013
District: 12
TOP: Estimated 1st Quarter of 2017
Architect: Consortium 168 Architects Pte Ltd
Carpark: 181 Carpark lots at 3rd to 5th floor
Unit Types:
Shops: 21-84 sqm (25 Units)
Restaurants: 26-445 sqm (26 units)
Medical Suites: 39-73 sqm (171 units)

About Royal Square

Discovering The DNA Of A World Class Medical Centre That Covers Every Aspect Of Life

  • 16 Levels Of Medical Suites
  • Mixed-use Development with Hotel and Mall
  • Communal Landscape Deck With Restaurants For Work-Life Balance.

Step into the most comprehensive medical destination in Novena medical hub. Comprising medical suites, a hotel, shops and restaurants, Royal Square attracts with its all-in-one efficiency that allows medical tourists and guests to conveniently rest at the 4-star hotel above, and get their daily needs at the mall below. Set apart by the thoughtfulness of such unique combination, Royal Square is the perfect choice for medical professionals.

Unveiling The Most Sought After Medical Suites That Stand In A Renowned Medical Arena.

  • Situated At Prime District 12
  • Next To The Future Health City Novena
  • Adjacent To Novena MRT Station

Royal Square is situated alongside the future Health City Novena, Singapore’s largest healthcare complex to be completed by 2030. The 17-hectare integrated development will incorporate 10 buildings, including Tan Tock Seng Hospital and 5 new healthcare facilities, connected via a network of MRT, pedestrian walkways and shutter bus services. The complex will also extend beyond healthcare to encompass education, commercial and leisure spaces.

In addition to existing medical centres, healthcare professionals can easily benefit from seamless coordination with clinical expertise, technologies and facilities nearby. This congregation of medical specialists will create a regionally renowned medical brand out of the Novena area.

Located amidst the future Health City Novena, Royal Square is set to draw visitors, medical tourists and business travellers from across the region. With a growing population of well-heeled city residents in proximity, supported by surrounding offices, medical facilities, schools and hotels, Royal Square is an astute medical address.

Revealing New Perspectives Of Lives In The Most Positive Light

  • Efficient Infrastructure That Enhances Medical Process.
  • Consists Of Day Surgery Centre, Imaging Centre and Laboratory Facilities
  • To Be Certified BCA Green Mark Platinum for promoting a sustainable workplace.

A dedicated lift lobby with 6 specialised medical lifts serves 171 units of medical suites with sizes ranging from 39sqm to 73sqm. The 15 medical floors are specially designed for healthcare professionals’ convenience, with features such as wide corridors and outward-facing units with optimum ventilation and abundant natural daylight. Being North-South oriented, the tower is exposed to minimal heat gain and glare.

Royal Square Location Map


View Larger Map

Royal Square Street View

Royal Square Resale/Rental Prices






Site Map & Floor Plans

Royal Square Site Map
Royal Square Unit Distribution Level 1
Royal Square Site Map
Royal Square Unit Distribution Level 1
Unit No. Unit Type Size No. of Unit Remarks
#01-01 Shop 21 1 Inc. 1 sqm A/C at 2nd Sty
#01-02 Shop 26 1 Inc. 1 sqm A/C at 2nd Sty
#01-03 Shop 36 1 Inc. 1 sqm A/C at 2nd Sty
#01-04 Restaurant 50 1 Inc. 3 sqm A/C at 4th Sty
#01-05 Restaurant 47 1 Inc. 3 sqm A/C at 4th Sty
#01-06 Restaurant 78 1 Inc. 3 sqm A/C at 4th Sty
#01-07 Restaurant 74 1 Inc. 3 sqm A/C at 4th Sty
#01-08 Restaurant 64 1 Inc. 3 sqm A/C at 4th Sty
#01-09 Restaurant 50 1 Inc. 3 sqm A/C at 4th Sty
#01-10 Restaurant 54 1 Inc. 3 sqm A/C at 4th Sty
#01-11 Restaurant 30 1 Inc. 3 sqm A/C at 4th Sty
#01-12 Restaurant 30 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-13 Restaurant 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-14 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-15 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-16 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-17 Shop 40 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-18 Restaurant 35 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-19 Restaurant 35 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-20 Restaurant 37 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-21 Shop 51 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-22 Shop 49 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-23 Shop 29 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-24 Shop 21 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-25 Restaurant 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-26 Restaurant 26 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#01-27 Restaurant 40 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
Royal Square Unit Distribution Level 2
Unit No. Unit Type Size No. of Unit Remarks
#02-01 Shop 56 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-02 Shop 50 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-03 Shop 50 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-04 Shop 50 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-05 Shop 84 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-06 Shop 75 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-07 Restaurant 248 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-08 Restaurant 51 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-09 Restaurant 52 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-10 Restaurant 52 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-11 Restaurant 52 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-12 Restaurant 63 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-13 Shop 42 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-14 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-15 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-16 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-17 Shop 40 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-18 Shop 22 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-19 Restaurant 65 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-20 Restaurant 57 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-21 Shop 33 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
#02-22 Shop 35 1 Central A/C. Purchaser may install roller shutter (design to be advised) at their own cost.
Royal Square Unit Distribution Level 6
Unit No. Unit Type Size No. of Unit Remarks
#06-01 Restaurant 445 1 Inc. 2 sqm Grease Trap (accessory lot) at 2nd Sty, 12 sqm PAHU (accessory lot) at 6th Sty
#06-02 Restaurant 240 1 Inc. 2 sqm Grease Trap (accessory lot) at 2nd Sty, 12 sqm PAHU (accessory lot) at 6th Sty
Royal Square Medical Suites Unit Distribution
Unit No. Unit Type Size No. of Unit Remarks
#10-01 to #21-01 Medical Suite 64 12 Inc. 3 sqm A/C
#10-02 to #21-02 Medical Suite 50 12 Inc. 2 sqm A/C
#10-03 to #21-03 Medical Suite 46 12 Inc. 2 sqm A/C
#10-04 to #21-04 Medical Suite 48 12 Inc. 2 sqm A/C
#10-05 to #21-05 Medical Suite 50 12 Inc. 3 sqm A/C
#10-06 to #21-06 Medical Suite 53 12 Inc. 3 sqm A/C
#10-07 to #21-07 Medical Suite 73 12 Inc. 3 sqm A/C
#10-08 to #21-08 Medical Suite 70 12 Inc. 3 sqm A/C
#10-09 to #21-09 Medical Suite 69 12 Inc. 3 sqm A/C
#10-10 to #21-10 Medical Suite 68 12 Inc. 3 sqm A/C
#10-11 to #21-11 Medical Suite 47 12 Inc. 3 sqm A/C
#10-12 to #21-12 Medical Suite 65 12 Inc. 3 sqm A/C
#10-13 to #21-13 Medical Suite 61 12 Inc. 3 sqm A/C
#10-14 to #21-14 Medical Suite 39 12 Inc. 3 sqm A/C

Specifications

Green Mark / Special Features 1. Music Staircase at 1st storey; between the development and covered linkway leading to Novena MRT / Velocity / Square 2 and underpass to IRAS Building 2. Landscape Facilities at 1st Storey a. Stainless Steel Water Columns b. Entry Plaza with Glass Floor Panels c. Stainless Steel Trough with Water Jets d. Stone Seatings e. Manicured Planting with Development Signage f. Accent Paving 3. Green corner for display of information on energy / water consumption / buildings’ green features 4. Provision of bicycle parking lots and shower facilities 5. Recycling bins at loading/unloading area 6. Communal Landscape Deck at 6th Storey a. Multi-Purpose Pavilion and Look Out Point b. Reflective Pool (0.3m depth) c. Raised Open Lawn d. Feature Light Box e. Water Cascades f. Green Cage g. Fitness Corner h. Waterwall i. Reflecting Pool with water Spigots j. Raised Seating 7. Handicap Toilet and Shower Facilities at 6th Storey Restaurant
Ceiling Height for 1st Storey 3.5m (estimated) except for #01-11 and #01-17
Ceiling Height for 2nd Storey 3.5m (estimated)
Structural Loading for 2nd Storey 4 KN/m2
Electrical Rating 40A – 200A TPN (please refer to specification for details)
Allowable Maximum Lighting Power Budget 15.0 W/m2
Shop
Ceiling Height for 1st Storey 3.5m (estimated)
Ceiling Height for 2nd Storey 3.5m (estimated)
Structural Loading for 2nd Storey 4 KN/m2
Electrical Rating 32A – 80A TPN (please refer to specification for details)
Allowable Maximum Lighting Power Budget 25.0 W/m2
Medical Suites
Ceiling Height 3.9m to 3.3m (estimated)
Structural Loading (max) 5 KN/m2
Electrical Rating 400V 3-phase supply for individual units.(please refer to specification for details)
Allowable Maximum Lighting Power Budget 8.0 W/m2

E-Brochure

Royal Square E-Brochure Royal Square Medical Suites E-Brochure